FLIR Si2-Pro™ Acoustic Imaging for Partial Discharge

The FLIR Si2-Pro™ acoustic imager helps identify leaks, electrical partial discharge, and early bearing issues to reduce downtime and improve safety.

Overview

The Flir Si2-Pro™ acoustic imaging for partial discharge helps you significantly lower costs associated with mechanical bearing issues and partial discharge on electrical equipment. It also enables you to drastically reduce leaks in your facilities, cutting down expenses related to compressed air and gas leaks. With the Si2 series, you’ll experience the best-in-class performance, decision support, fleet management, and enterprise data integration available.


Key Features

  • Pressurized Leak Detection with Cost Quantification
    Detects industrial gas and compressed air leaks while estimating leak rate and annual cost to prioritize repairs and savings.

  • Partial Discharge Detection with Severity Assessment
    Provides on-camera severity assessment and type classification to support faster electrical PD evaluation and safer decision-making.

  • Mechanical Fault Detection
    Identifies early bearing issues to help prevent unplanned downtime and costly repairs.

  • High-Performance Acoustic Imaging for Fast Inspections
    124 microphones with automatic frequency tuning, 8× digital zoom, and a 12 MP camera enable confident detection from a safe distance.


Ideal Applications

  • Routine Inspections & Preventative Maintenance
    Ideal for recurring inspection routes across industrial facilities to identify issues early and reduce unplanned downtime.

  • Compressed Air & Industrial Gas Leak Detection
    Locate leaks quickly, quantify leak rate and cost, and prioritize repairs to reduce energy waste and operating expenses.

  • Electrical Partial Discharge Detection (High-Voltage Systems)
    Identify and classify partial discharge activity to support safer maintenance decisions and reduce risk of failure.

  • Mechanical Fault Detection (Bearings & Rotating Equipment)
    Detect early bearing faults to plan repairs proactively and avoid costly equipment downtime.

  • Safety & Compliance Support
    Helps teams identify potential hazards in gas systems and rotating assets to support safer operations and inspection standards.


Spec Summary

Feature Details
Acoustic Sensor 124 low-noise MEMS microphones with real-time sound visualization
Detection Range 0.3 m to 200 m (1.0 ft to 656 ft)
Frequency Range 2–130 kHz bandwidth
Directional Resolution From 1° up to 0.125°
Leak Detection Automatic leak recognition with estimated leak size and annual cost
Leak Rate Sensitivity Detects as low as 0.0032 l/min from 2.5 m and 0.0044 l/min from 6 m
Gases Detected Detects pressurized gases; quantifies compressed air, ammonia, argon, CO₂, helium, hydrogen, methane, natural gas, and nitrogen
Partial Discharge Detection AI-based severity assessment with recommended actions and type classification
Mechanical Fault Detection Mechanical fault mode for early identification of bearing issues
Digital Camera 12 MP color camera; 75° diagonal field of view
Zoom 8× digital zoom
Video Performance Digital camera: 60 fps; acoustic image: 30 fps; screen: 70 fps
Display 5-inch touchscreen (1280 × 720)

For specialized needs, you can choose from additional models: opt for the Si2-LD for advanced leak detection and mechanical fault detection applications or select the Si2-PD for your electric utility applications. Explore these models in the related products section below to find the perfect fit for your requirements.

 